Resources to help you with your choice of surfacing product
Addastone PLUS Resin Bonded - Typical depth 5-7mm depending on aggregate size
Base Course of 50-60mm AC20 Dense Bin 100/150
Plus
A 25-30mm AC6 Dense Surf 100/150 (+/- 6mm). Laid by others in well compacted layers to minimum fall of 1:40 to 1:60.
Vacuum Assisted Captive Shot Blasting to remove dirt and residue from the surface to ensure a good key.
Sub-base: Should be 100-150mm
(minimum 100mm) or as specified for the
site conditions by a qualified engineer
If required
Existing
Addastone PLUS Resin Bonded - Typical depth 5-7mm depending on aggregate size
60-70mm AC20 Dense Bin 100/150
Plus
A 30mm AC6 Dense Surf 100/150 or AC10 Dense Surf 100/150 (+/- 6mm) Laid by others in well compacted layers to minimum fall of 1:40 to 1:60.
Vacuum Assisted Captive Shot Blasting to remove dirt and residue from the surface to ensure a good key
Sub-base: Should be 100-150mm (minimum 100mm) or as specified for the site conditions by a qualified engineer
As required
Existing
Addastone PLUS Resin Bonded - Typical depth 5-7mm depending on aggregate size
120mm AC20 Dense Bin 100/150
Plus
A 30-40mm AC6 Dense Surf 100/150 or AC10 Dense Surf 100/150 (+/- 6mm) Laid by others in well compacted layers to minimum fall of 1:40 to 1:60.
Vacuum Assisted Captive Shot Blasting to remove dirt and residue from the surface to ensure a good key.
Sub-base: Should be 100-150mm (minimum 100mm) or as specified for the site conditions by a qualified engineer
As required
Existing
Addastone PLUS Resin Bonded - Typical depth 5-7mm depending on aggregate size
100-200 mm AC32 Dense base/Bin 100/150
Plus
A 30-40mm AC6 Dense Surf 100/150 or AC10 Dense Surf 100/150 (+/- 6mm) Laid by others in well compacted layers to minimum fall of 1:40 to 1:60.
Vacuum Assisted Captive Shot Blasting to remove dirt and residue from the surface to ensure a good key.
Sub-base: Should be 100-150mm (minimum 100mm) or as specified for the site conditions by a qualified engineer
As required
Existing
PU Addastone Plus Resin Bonded at typical depth 5mm using 1-3mm aggregate size
EP Addastone primer approx depth 0.3-0.5mm which has been scattered with quartz grit and left to cure to provide key.
(Coverage of quartz grit 50-70% of primer surface}
Concrete Course at a depth as required to take expected traffic loading.
Prepare concrete surface by Vacuum Assisted Diamond Grinding or Shot Blasting
Do not apply Addastone Plus system over movement joints. Ideally, joint material should be placed after application of the Addastone Plus system.
As required
As required
Existing